Our commission should be to provide our customers and consumers with ideal top quality and aggressive portable digital products for Indoor Substation And Outdoor Substation, 24kv Indoor Switchgear, Gis Gas Insulated Substation, We intention at Ongoing system innovation, management innovation, elite innovation and market place innovation, give full play into the overall advantages, and frequently strengthen services excellent.
Manufacturer for 160kva Transformer - S11-M Oil immersed distribution outdoor transformer – Nady Detail:

Compared with the original SZ11, the average of SZ13no-load loss reduced by 20% or more, the no-load current is reduced by 25% or more, operating costs dropped by an average of more than 15%

Relative to the conventional S11 type/S13 series three-phase double-winding and excitation surge of transformer power after manual voltage regulator, SZ11 SZ13 type series transformer can realize the load, through the controller on the ground remote power transformer to adjust the voltage, which can realize free power voltage regulator, reducing frequency of climbing and risk, greatly convenient for power operation personnel on site.

ttb

Rated

1. Capacity: 10kVA up to 31500kVA

2. High Voltage: 3.3kV up to 35kV

3. Connection Method: Optional

4.Rated Low Voltage: 0.4kV 3.15kV 6.3kV 6.6kV10.5kV

5.Rated frequency:50Hz

6.HV tap range: ±2.5%, ±5%

7.Material: Full copper Winding

Service conditions of Oil immersed distribution outdoor transformer

Device types:

outdoor type

Ambient temperature:

Maximum

+40°C

Maximum 24 hour average

+35°C

Minimum

-25°C (-45°C when you order details0

Ambient humidity:

Height above sea level at site

less than 1000m

Earthquake intensity

less than 8 degree

Height above sea level

less than 1000m

Mounting ambicnt:

No fire, explosion, earthquake and chemical corrosion environments.

Technical parameters of S11-M

1. S11-M Type 6~11 kV
Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
30
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500
6
6.3
6.6
10
10.5
11
±5%
±2×2.5%
0.4 Dyn11
Yzn11
Yyn0
80
100
110
130
150
170
200
240
290
340
410
480
570
700
830
970
117015501830
630/600
910/870
1090/1040
1310/1250
1580/1500
1890/1800
2310/2200
2730/2600
3200/3050
3830/3650
4520/4300
5410/5150
6200
7500
10300
12000
145001830021200
1.8
1.6
1.6
1.5
1.4
1.4
1.3
1.2
1.2
1.1
1.1
1.0
0.9
0.8
0.8
0.7
0.60.40.4
4
4
4
4
4
4
4
4
4
4
4
4
4.5
4.5
4.5
4.5
4.55.05.0
Dyn11
Yyn0
63080010001250

1600

2000

2500

3150

66.31010.5

 

±5%
±2×2.5%
33.156.3  Yd11Dyn11 820100011801400

1680

2010

2370

2800

69208460991011700

14100

16900

19600

23000

0.600.600.600.50

0.40

0.40

0.40

0.40

5.5
400050006300 1010.5 3.156.3 345041004890 273003130035000 0.400.400.40

2. S11-M Type 20 kV
Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
50
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500
20
22
24
±5%
±2×2.5%
0.4 Dyn11
Yyn0Yzn11
100
150
170
200
240
290
340
410
480
570
700
830
970
117015501830
1270/1210
2120/2020
2500/2380
2970/2830
3500/3330
4160/3960
5010/4770
6050/5760
7280/6930
8280
9900
12150
14670
175501914022220
2.0
1.80
1.70
1.60
1.50
1.40
1.40
1.30
1.20
1.10
1.00
1.00
0.90
0.800.600.50
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
6.0
6.0
6.0
6.0
6.06.06.0

3. S11-M Type 38.5kV

Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
50
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500
3538.5 ±5%
±2×2.5%
0.4 Dyn11
Yyn0
170
230
270
290
340
410
490
580
690
830
980
1150
1410
170015901890
1270/1210
2120/2020
2500/2380
2970/2830
3500/3330
4160/3960
5010/4770
6050/5760
7280/6930
8280
9900
12150
14670
175501970023200
2.0
1.80
1.70
1.60
1.50
1.40
1.40
1.30
1.20
1.10
1.00
1.00
0.90
0.800.750.75
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.56.56.5
63080010001250

1600

2000

2500

35 ±5%
±2×2.5%
3.156.310.5  Yd11 83098011501400

1690

2170

2560

786094001150013900

16600

18300

19600

0.650.650.650.55

0.45

0.45

0.45

6.5
3150400050006300 3538.5 ±5%
±2×2.5%
3.156.310.5 3040361043205240 23000273003130035000 0.450.450.450.45 7.07.07.08.0
8000100001250016000

20000

25000

31500

3538.5 ±5%
±2×2.5%
3.153.36.36.6

10.5

YNd11 720087001000012100

14400

17000

20200

38400453005380065800

79500

94000

112000

0.350.350.30.3

0.3

0.25

0.25

8.08.08.08.0

8.0

10.0

10.0

Structural drawing of S11-M Type

fg

Main Functions And Features

1. The low-voltage winding is of cylindrical or spiral structure, with high mechanical strength and good short-circuit resistance.

2. The corrugated oil tank is adopted to replace the oil conservator. The oil tank cover and the oil tank are all welded along the edge or fastened with bolts, thus prolonging the service life of the transformer oil.

3. After oil removal, embroidery removal and phosphating treatment, the product is sprayed with three times of primer and one time of finish paint inside and outside. The product is salt fog proof, damp heat proof and fungus proof, which can meet the special requirements of metallurgy, petrochemical system and wet and polluted areas. It is beautiful and reliable.

4. The transformer oil tank is fully sealed, and equipped with pressure reducing valve, signal thermometer, gas relay, etc according to the standard requirements to ensure the safe operation of the transformer.

5. This series of products are beautiful in appearance, small in size, and can reduce the installation area. It is an ideal maintenance-free distribution product.

6.We employ spiral coil with longitudinal oil path to make a better interior cooling effect;

e


Product detail pictures:

Manufacturer for 160kva Transformer - S11-M Oil immersed distribution outdoor transformer – Nady detail pictures

Manufacturer for 160kva Transformer - S11-M Oil immersed distribution outdoor transformer – Nady detail pictures

Manufacturer for 160kva Transformer - S11-M Oil immersed distribution outdoor transformer – Nady detail pictures

Manufacturer for 160kva Transformer - S11-M Oil immersed distribution outdoor transformer – Nady detail pictures


Related Product Guide:

Dedicated to strict quality management and thoughtful client services, our experienced staff customers are generally available to discuss your demands and guarantee full client pleasure for Manufacturer for 160kva Transformer - S11-M Oil immersed distribution outdoor transformer – Nady , The product will supply to all over the world, such as: Mombasa, Thailand, French, "Good quality and reasonable price" are our business principles. If you are interested in our products or have any questions, make sure you feel free to contact us. We hope to establish cooperative relationships with you in the near future.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Vanessa from Slovenia - 2018.09.21 11:44
    The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Marcie Green from Anguilla - 2017.05.02 11:33