PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We will make every effort to be outstanding and perfect, and accelerate our steps for standing in the rank of international top-grade and high-tech enterprises for Smart Substation, High Voltage Cb, Small Substation, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady Detail:

• Standards: IEC60076,IEC1330,ANSI/IEEE C57.12.00 ,C57.12.20 ,C57.12.90,BS171,SABS 780
• The box type substation is  based on  advantage of European box YBW substation,which reduces the cost,and solves such defects ad high cost,incomplete protection and poor ventilation and radiation of the European products.
• The products is applicable for various wind power plants and is the best fitted product for wind power generation system.

rt

Service conditions of American box type substation

Normal service conditions of substationas follows:
Ambient temperature:
Maximum +40°C
Maximum 24 hour average +35°C
Minimum (according to minus 15 indoor classes) -25°C
Ambient humidity:
Daily average relative humidity less than 95%
Monthly average relative humidity less than 90%
Earthquake intensity less than 8 degree
Height above sea level less than1000m

This product should not be used under conditions of fire, explosion, earthquake and chemical corrosion environments.

Technical specification of American box type substation

No.

Description

Data

1

General

Standard of production & testing

IEC62271-1, IEC62271-200,IEC62271-202,IEC60076,IEC61439, IEC60529,IEC62262, IEC60721

Composition of distribution substation

No. of medium voltage compartment

1

No. of transformer compartment

1

no. of low voltage compartment

1

 

2

Medium Voltage compartment

protection class

IP43

Service rated voltage ( kV) Available

15  ( suitable in  10 , 11, 13.8,) KV

Voltage variation of the system, %

10%

1min power frequency withstand voltage (to-ground/between open contacts) 32/36 42/48
Lightning impulse withstand voltage (to-ground/between open contacts) 60/70 75/85

2.1

Ring Main Unit (RMU)

incoming 2 + outgoing 1  (can be choosed & decided by the clients)

load break switch with earthing switch

2

type

SF6

Frequency

50/ 60 Hz

Power frequency withstand voltage ,kV(Rms)

38

Rated lightning impulse withstand voltage,kV (Peak)

95

rated current

630 A

Rated short-time withstand current for 1s

25 kA

2.2

Vacuum circuit breaker with earthing switch and isolator

1

type

vacuum

nominal voltage

15kV( suitable in 10 , 11, 13.8, )

Rated power frequency withstand voltage

38 kV

Rated lightning impulse withstand voltage

95kV

Current rating, A

Depends on the rating of the transformer

Rated short-time withstand current for 1S

25kV

2.3

High voltage load disconnecting switch + fuse

1

type

Air insulated

nominal voltage

15kV

Rated power frequency withstand voltage

42 kV

Rated lightning impulse withstand voltage

75 kV

rated current

630 A

Fuse rated voltage

12kV

Fuse rated Solution  current

40,100,125

 

3

Low Voltage compartment

Size of cubicle

protection class

IP 23

Main ACB (Air circuit breaker)

Nominal voltage

400 V

Rated frequency

50 /60 Hz

Power frequency withstand voltage, kV (RMS)

3 for one minute

rated lightning impulse withstand voltage, kV(Peak)( 1.2 /50 ms)

rated current (Amp)

2500

rated short-time current rating

50 KA

3.1

MCCB /ACB

Nominal voltage

0.4 KV

Rated current

2500 A

Rated short-time current rating

50 KA

3.2

Current Transformer ( CT)

QTY for each s/s

3

voltage rating

380V

current transformer ratio

2500 /5 A

Frequency

50 /60 Hz

Burden

15 VA

Class

1

3.3

Ammeter

qty

3

current range

0 -2500 A

3.4

Voltmeter with selector switch

1

voltage range

0 -500 V

 

4

Transformer backpack

protection class

IP 23

Technical characteristics of the distribution transformer

cooling method

Air cooling

NO. OF phase

3

standard

IEC 60076

Frequency

50 /60 Hz

rated continuous power on HV & LV side

2500 KVA  (depends on the requirements of the client)

Rated voltage on HV side

15 KV( suitable in 10 , 11, 13.8, 20, 24, 30, 33 , 35 ,36 )

Rated voltage on LV side

0.4 KV

Vector group

Dyn5 ( or Dyn11..etc)

No-load loss at rated voltage and frequency

≤ 0. 95 KW

Full load loss , KW

≤ 11.0

Color of the transformer

gray

Thickness of surface treatment (µm)

140

Ability to withstand unbalanced load

≥ 90 %

Average temperature rise  , windings /top oil

60  /55

windings material

100% copper

Structural drawing

fas
gfa

The feature

1. Strong overload capacity, allowing overload 2 times 2 hours, overload 1.6 times 7 hours without affecting the variable life of the box.

2.Adopt elbow type plug connector, can be very convenient to connect the high-voltage incoming cable, and can be used as load switch in emergency, can be charged plug.

3.Adopt double fuse protection, insert fuse is short circuit fault of double sensitive fuse (temperature, current) protection box.

4.Backup Current Limiting Protection Fuses (ELSP) are used to protect the high voltage side when a fault occurs inside the protection box.

5.Transformers generally use high ignition point oil.

6.All components used for high voltage load switch protection, such as fuse, transformer core and winding, are placed in the same oil tank


Product detail pictures:

PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady detail pictures

PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady detail pictures

PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady detail pictures

PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady detail pictures

PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady detail pictures

PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization for that long-term to establish jointly with customers for mutual reciprocity and mutual gain for PriceList for Ggd - American box type YBW series prefabricated compact substation – Nady , The product will supply to all over the world, such as: belarus, Gambia, Madras, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to for you of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we are going to have a bright prospect and to be distributed all over the world in the years to come.
  • The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Sahid Ruvalcaba from Plymouth - 2018.10.01 14:14
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Margaret from Uzbekistan - 2017.10.25 15:53