SZ11 SZ13 intelligent adjusted Oil immersed distribution outdoor transformer

Short Description:

  • This product conforms to the national standard GB1094.1-2013(IEC 60076) power transformer and GB / T6451-2015 three phase oil immersed power transformer technical parameters and requirements. The three-phase oil -immersed distribution transformer applies new type insulating structure. The iron core is made of high-quality cold-rolled silicon-steel plate. High-voltage winding group is made up of high-quality oxygen-free copper lines and it adopts multi-layer drum type structure. All fasteners have been processed with special treatment to prevent them from loosening.
  • As high-tech product that promoted by the country, the product has many advantages such as high efficiency, low loss. Its social benefits are remarkable that it will save much of electricity consumption and operating cost.

Product Detail

Product Tags

Compared with the original SZ11, the average of SZ13no-load loss reduced by 20% or more, the no-load current is reduced by 25% or more, operating costs dropped by an average of more than 15%

  Relative to the conventional S11 type/S13 series three-phase double-winding and excitation surge of transformer power after manual voltage regulator, SZ11 SZ13 type series transformer can realize the load, through the controller on the ground remote power transformer to adjust the voltage, which can realize free power voltage regulator, reducing frequency of climbing and risk, greatly convenient for power operation personnel on site.

qw

Rated

1. Capacity: 10kVA up to 31500kVA

2. High Voltage: 3.3kV up to 35kV

3. Connection Method: Optional

4.Rated Low Voltage: 0.4kV 3.15kV 6.3kV 6.6kV10.5kV

5.Rated frequency:50Hz

6.HV tap range: ±2.5%, ±5%

7.Material: Full copper Winding

Service conditions of Oil immersed distribution outdoor transformer

Device types:

outdoor type

Ambient temperature:

Maximum

+40°C

Maximum 24 hour average

+35°C

Minimum

-25°C (-45°C when you order details0

Ambient humidity:

Height above sea level at site

less than 1000m

Earthquake intensity

less than 8 degree

Height above sea level

less than 1000m

Mounting ambicnt:

No fire, explosion, earthquake and chemical corrosion environments.

Technical parameters of SZ11 SZ13

1. SZ11-M Type 6~11 kV
Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
30
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500

 

6
6.3
6.6
10
10.5
11
±5%
±2x2.5%
0.4 Dyn11
Yzn11
Yyn0
80
100
110
130
150
170
200
240
290
340
410
480
570
700
830
970
117015501830

 

630/600
910/870
1090/1040
1310/1250
1580/1500
1890/1800
2310/2200
2730/2600
3200/3050
3830/3650
4520/4300
5410/5150
6200
7500
10300
12000
145001830021200

 

1.8
1.6
1.6
1.5
1.4
1.4
1.3
1.2
1.2
1.1
1.1
1.0
0.9
0.8
0.8
0.7
0.60.40.4

 

4
4
4
4
4
4
4
4
4
4
4
4
4.5
4.5
4.5
4.5
4.55.05.0

 

Dyn11
Yyn0
6308001000

1250

1600

2000

2500

3150

 

66.310

10.5

 

±5%
±2x2.5%
33.156.3

 

Yd11Dyn11  82010001180

1400

1680

2010

2370

2800

 

692084609910

11700

14100

16900

19600

23000

 

0.600.600.60

0.50

0.40

0.40

0.40

0.40

 

5.5
400050006300

 

1010.5 3.156.3 345041004890

 

273003130035000

 

0.400.400.40

 

2. SZ11-M Type 20 kV
Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
50
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500

 

20
22
24
±5%
±2x2.5%
0.4 Dyn11
Yyn0Yzn11

 

100
150
170
200
240
290
340
410
480
570
700
830
970
117015501830

 

1270/1210
2120/2020
2500/2380
2970/2830
3500/3330
4160/3960
5010/4770
6050/5760
7280/6930
8280
9900
12150
14670
175501914022220

 

2.0
1.80
1.70
1.60
1.50
1.40
1.40
1.30
1.20
1.10
1.00
1.00
0.90
0.800.600.50

 

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
6.0
6.0
6.0
6.0
6.06.06.0

 

3. SZ11-M Type 38.5kV

Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
50
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500

 

3538.5 ±5%
±2x2.5%
0.4 Dyn11
Yyn0
170
230
270
290
340
410
490
580
690
830
980
1150
1410
170015901890

 

1270/1210
2120/2020
2500/2380
2970/2830
3500/3330
4160/3960
5010/4770
6050/5760
7280/6930
8280
9900
12150
14670
175501970023200

 

2.0
1.80
1.70
1.60
1.50
1.40
1.40
1.30
1.20
1.10
1.00
1.00
0.90
0.800.750.75

 

6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.56.56.5

 

6308001000

1250

1600

2000

2500

 

35 ±5%
±2x2.5%
3.156.310.5

 

Yd11 8309801150

1400

1690

2170

2560

 

7860940011500

13900

16600

18300

19600

 

0.650.650.65

0.55

0.45

0.45

0.45

 

6.5
315040005000

6300

 

3538.5 ±5%
±2x2.5%
3.156.310.5

 

304036104320

5240

 

230002730031300

35000

 

0.450.450.45

0.45

 

7.07.07.0

8.0

 

80001000012500

16000

20000

25000

31500

3538.5 ±5%
±2x2.5%
3.153.36.3

6.6

10.5

 

YNd11 7200870010000

12100

14400

17000

20200

 

384004530053800

65800

79500

94000

112000

 

0.350.350.3

0.3

0.3

0.25

0.25

 

8.08.08.0

8.0

8.0

10.0

10.0

SZ13-M Type 6~10 kV
Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
30
50
63
80
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500
6
6.3
6.6
10
10.5
11
±5%
±2x2.5%
0.4 Dyn11
Yzn11
Yyn0
80
100
110
130
150
170
200
240
290
340
410
480
570
700
830
970
117015501830
630/600
910/870
1090/1040
1310/1250
1580/1500
1890/1800
2310/2200
2730/2600
3200/3050
3830/3650
4520/4300
5410/5150
6200
7500
10300
12000
145001830021200
1.8
1.6
1.6
1.5
1.4
1.4
1.3
1.2
1.2
1.1
1.1
1.0
0.9
0.8
0.8
0.7
0.60.40.4
4
4
4
4
4
4
4
4
4
4
4
4
4.5
4.5
4.5
4.5
4.55.05.0
Dyn11
Yyn0

SZ13-M Type 20 kV
Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
50
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500
20
22
24
±5%
±2x2.5%
0.4 Dyn11
Yyn0Yzn11

 

100
150
170
200
240
290
340
410
480
570
700
830
970
117015501830
1270/1210
2120/2020
2500/2380
2970/2830
3500/3330
4160/3960
5010/4770
6050/5760
7280/6930
8280
9900
12150
14670
175501914022220
2.0
1.80
1.70
1.60
1.50
1.40
1.40
1.30
1.20
1.10
1.00
1.00
0.90
0.800.600.50
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
6.0
6.0
6.0
6.0
6.06.06.0

SZ13-M Type 35 kV
Performance parameters

Rated capacity(KVA) Voltage Combination and  tap  range connection of transformer winding No-load loss(W) Load loss (W) No-load current (%) Short circuit impedance (%)
High voltage
(KV)
High voltage tap range
( %)
Low voltage
(KV)
50
100
125
160
200
250
315
400
500
630
800
1000
1250
160020002500
3538.5 ±5%
±2x2.5%
0.4 Dyn11
Yyn0
170
230
270
290
340
410
490
580
690
830
980
1150
1410
170015901890
1270/1210
2120/2020
2500/2380
2970/2830
3500/3330
4160/3960
5010/4770
6050/5760
7280/6930
8280
9900
12150
14670
175501970023200
2.0
1.80
1.70
1.60
1.50
1.40
1.40
1.30
1.20
1.10
1.00
1.00
0.90
0.800.750.75
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.5
6.56.56.5

Structural drawing of SZ11-M Type

s

Main Functions And Features

1. The low-voltage winding is of cylindrical or spiral structure, with high mechanical strength and good short-circuit resistance.

2. The corrugated oil tank is adopted to replace the oil conservator. The oil tank cover and the oil tank are all welded along the edge or fastened with bolts, thus prolonging the service life of the transformer oil.

3. After oil removal, embroidery removal and phosphating treatment, the product is sprayed with three times of primer and one time of finish paint inside and outside. The product is salt fog proof, damp heat proof and fungus proof, which can meet the special requirements of metallurgy, petrochemical system and wet and polluted areas. It is beautiful and reliable.

4. The transformer oil tank is fully sealed, and equipped with pressure reducing valve, signal thermometer, gas relay, etc according to the standard requirements to ensure the safe operation of the transformer.

5. This series of products are beautiful in appearance, small in size, and can reduce the installation area. It is an ideal maintenance-free distribution product.

6.We employ spiral coil with longitudinal oil path to make a better interior cooling effect;

Structural drawing of SZ13-M Type

10kv to 22kv Transformer Structure

ccc

30kv to 35kv Transformer Structure

aaa

  • Previous: