Using a complete scientific top quality management program, great high-quality and fantastic religion, we win great track record and occupied this area for Electrical Panel, 11kv Pole Mounted Substation, Pad Mounted Transformer, If you are fascinated in any of our products, you should come to feel no cost to call us for more aspects. We hope to cooperate with a lot more close friends from all over the world.
Trending Products Ring Main Unit Switchgear - KYN28A-12/24 12kV 24kV Medium Voltage Indoor Metal-clad Switchgear – Nady Detail:

8

Service conditions of indoor Metal-clad Switchgear

Normal service conditions of switchgear as follows:
Ambient temperature:
Maximum

+40°C

Maximum 24 hour average

+35°C

Minimum (according to minus 15 indoor classes)

-15°C

Ambient humidity:
Daily average relative humidity

less than 95%

Monthly average relative humidity

less than 90%

Earthquake intensity

less than 8 degree

Height above sea level

less than 1000m

This product should not be used under conditions of fire, explosion, earthquake and chemical corrosion environments.

Special service conditions

Each special service condition should be proposed in advance and confirmed by the manufacturer and user.

The dielectric strength of the air will be reduced in when altitude is over 1000m at site.

If the ambient temperature is over the maximum degree, the capacity of the using current must be lower than the designed currents for both main bus-bar and branching bus bar. The installation of area is propitious to reduce heat.

ccv

 Technical specification of KYN28-12 /24switchgear

No Item Unit Parameter
1 Rated voltage kV 7.2kV, 12kV, 17.5kV, 24kV
2 Rated frequency Hz 50/60
3 Rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000
4 Branch bus-bar rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000
5 Main bus-bar rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000
6 1 min power frequency withstand voltage(wet/dry) kV 38/48, 50/60/60/65
7 Lightning impulse withstand voltage kV 75, 95/125
8 Rated short circuit breaking current(peak) kA 40/50/63/80/100
9 Short time withstand current(4s) kA 20/25/31.5/40
10 Protection type Enclosure:IP4X,Between compartment:IP2X

Structure & Basic Components of Switchgear

KYN28 JIEGOUTU

1. Enclosure 2. Sub-bus-bar 3. Main bus-bar bushing 4. Main bus-bar
5. Fixed contact assembly 6. Fixed contact box 7. Current transformer (CT) 8. Earth-switch
9. Cable 10. Surge arresters (not installed) 11. Bus-bar of earthing 12. Isolating plate
13. Partition (shutter) 14. Secondary circuit plug 15. CB truck (cart) 16. Heater
17. Draw-out type horizontal isolating plate 18. Earth switch operating mechanism 19. Control cable groove 20. Pressure releasing device

 

Outline dimension

Height

2300

width

Rated current 1250A and below

800

Rated current 1600A and Above

1000

depth

Cable inlet and outlet

1500

Overhead inlet and outlet

1660

 

Mounting dimension

Cabinet width A

Cabinet depth B

L1

L2

L3

L4

800

1500 (Cable)

530

630

150

490

1660(Overhead)

530

630

310

650

1000

1500 (Cable)

730

830

150

490

1660(Overhead)

730

830

310

650

fffff

Product Features

1.The cabinet structure is made of aluminum-zinc plate after being machined by CNC machine tool using multiple bending process;

2.All operations are carried out under the closed state of the door;

3. High protection level can prevent the intrusion of debris and insects;

4.simple and effective five-proof locked to prevent misoperation. It can be equipped with VS1 and VD4 vacuum circuit breakers.

5.It features with simple replacement of circuit breaker, good hand truck interchangeability, wall-installation and cabinet front maintenance

6.It  features with lower floor space, enough space for cable room, multiple cables connection. Heaters can be installed in the circuit breaker and cable room to prevent condensation and corrosion.


Product detail pictures:

Trending Products Ring Main Unit Switchgear - KYN28A-12/24 12kV 24kV Medium Voltage Indoor Metal-clad Switchgear – Nady detail pictures

Trending Products Ring Main Unit Switchgear - KYN28A-12/24 12kV 24kV Medium Voltage Indoor Metal-clad Switchgear – Nady detail pictures

Trending Products Ring Main Unit Switchgear - KYN28A-12/24 12kV 24kV Medium Voltage Indoor Metal-clad Switchgear – Nady detail pictures

Trending Products Ring Main Unit Switchgear - KYN28A-12/24 12kV 24kV Medium Voltage Indoor Metal-clad Switchgear – Nady detail pictures

Trending Products Ring Main Unit Switchgear - KYN28A-12/24 12kV 24kV Medium Voltage Indoor Metal-clad Switchgear – Nady detail pictures


Related Product Guide:

Our firm promises all consumers with the first-class products as well as most satisfying post-sale services. We warmly welcome our regular and new consumers to join us for Trending Products Ring Main Unit Switchgear - KYN28A-12/24 12kV 24kV Medium Voltage Indoor Metal-clad Switchgear – Nady , The product will supply to all over the world, such as: Indonesia, Guatemala, Kuwait, What is good price? We provide customers with factory price. In the premise of good quality, efficiency will have to be paid attention to and maintain appropriate low and healthy profits. What is a fast delivery? We make the delivery according to customers' requirements. Although delivery time depends on the order quantity and the complexity of it, we still try to supply products and solutions in time. Sincerely hope we could have long term business relationship.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Irma from Indonesia - 2017.03.28 12:22
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Marcie Green from Italy - 2018.02.12 14:52